76
CTC EcoZenith i350
Room temp reduced (°C)
-2 (0 to -40)
“Room temp reduced” is displayed if a room sensor is
installed.
This setting defines how many degrees the room
temperature will be reduced by during the various
scheduled reduction periods, e.g. Night reduction,
Holiday, etc.
Primary flow reduced (°C)
-3 (0...-40)
If there is no room sensor installed, “Primary flow
reduced” is displayed instead.
Alarm room temp °C
5 (-40 to 40)
When the room temperature is too low, the message
Low room temperature alarm is displayed.
Smart low price °C
1 (Off/1 to 5)
Setting to increase adjustment at low energy price,
via Smart Grid. Find out more in the section entitled
“Define/Remote control/Smart Grid”.
Smart over capacity °C
2 (Off/1 to 5)
Setting to increase adjustment at over capacity energy
price, via Smart Grid. Find out more in the section
entitled “Define/Remote control/Smart Grid”.
Max time heating (min)
20 (10 to 120)
This is the maximum time spent by the heat pump
charging the heating circuit if heat is needed in the hot
water tank.
Charge pump %
60 (Off/25 to 100)
Setting for charge pump (G11) speed when charging
the heating circuit.
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...