11.9
Electric heater
Max el. heater kW
9.0 (0 to 11.9)
Maximum permitted output from electric immersion
heater.
Max el. heater DHW kW
0.0 (0 to 11.9)
Maximum permitted output from the immersion heater
when charging hot water. Can be set to the available
power settings for the model.
Start at degree minute
-500 (-900 to -30)
This states at which degree minute the electric
immersion heater will start.
Diff step, degree minute
-50 (-20 to -300)
This states the difference in degree minutes between
the increments of output for the immersion heater. The
output of the immersion heater is Max el. heater kW
divided into 10 increments.
Main fuse A
20 (10 to 90)
The property’s main fuse size is set here. This setting
and the fitted current sensors ensure the fuses are
protected when using appliances which generate
temporary power peaks, for example, cookers, ovens,
engine heaters, etc. The product temporarily reduces
power drawn where this type of equipment is being
used.
Conv. factor curr. sensors
1 (1 to 10)
This menu contains the factor the current sensor is to
use. This setting is only performed if the connection has
been installed for a current sensor for higher currents.
Tariff, el.
Off (On/Off)
Find out more in the section entitled “Smart Grid”.
Smart block immersion
Off (On/Off)
Find out more in the section entitled “Smart Grid”.
Dansk
Nederlands
Čeština
Eesti
Polski
Slovenščina
Svenska
Norsk
English
Deutsch
Suomi
Française
Electric heater
Max el. heater kW
9.0
Max el. heater DHW kW
0.0
Start at degree minute
-500
Diff step, degree minute
-50
Main fuse A
20
Conv. factor curr. sensors
1
Tariff EL
Off
Smart block immersion
Off
Settings language
Settings language
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...