75
CTC EcoZenith i350
Example:
“Inclination 50” means that the temperature of the water
supplied to the radiators will be 50°C when the outdoor
temperature is -15°C, if the adjustment is set to 0. If the
adjustment is set to +5, the temperature will be 55°C
instead. The curve is increased by 5°C at all outdoor
temperatures, i.e. the curve is parallel offset by 5°C.
Heating mode
Auto/On/Off
Switching of heating season or summer season can
take place automatically (auto) or a selection can be
made here to set the heating to be on or off.
Auto = the switch between heating season (On) and
summer mode (Off) takes place automatically
On = (not summer mode) = Continuous heating season,
Constant radiator flow.
Off = there is no heating, radiator flow stops.
In the meny that is described below (
Heating off,
out °C), the specific outdoor temperature value for
changing between heating season and summer mode,
is selected.
Heating mode, ext
--/Auto/On/Off
Switching between heating and summer mode can be
controlled remotely. Find out more in the section entitled
“Define/Remote control”.
Heating off, out (°C)
18 (10 to 30)
Outdoor temperature limit at which the house no longer
requires heating. The radiator pump stops. The radiator
pump (G2) is activated daily for a short period to reduce
the risk of jamming. The system restarts automatically
when heating is required.
Heating off, time (°C)
120 (30 to 240)
The delay period before the radiator pump (G2) stops as
described above.
Inclination (default setting)
50 (25 to 85)
Inclination means the temperature your property needs
at different outdoor temperatures. See more detailed
information about this in the section entitled “Your
home’s heating settings”. The value set corresponds
to the temperature of the radiators when the outdoor
temperature is -15°C. After this default setting, fine
adjustment takes place in the “Room temperature”
menu.
Adjustment
0 (-20 to 20)
The curve adjustment means that the temperature
level can generally be raised or lowered at all outdoor
temperatures. After this default setting, fine adjustment
takes place in the “Room temperature” menu.
Night reduction disable ºC
5 (-40 to 40)
When the outdoor temperature is lower than this, night
reduction is deactivated. This menu overrides remote
control.
i
There is no radiator pump
in heating circuit 1. Instead,
“Heating, mode” is controlled by
the diverting valve.
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...