53
CTC EcoZenith i350
low
[l/s]
copper pipe 22 mm [m]
copper pipe 28 mm [m]
copper pipe 35 mm [m]
0.1
>20
>20
>20
0.12
>20
>20
>20
0.14
>20
>20
>20
0.17
21
>20
>20
0.19
17
>20
>20
0.22
12
>20
>20
0.24
10
>20
>20
0.26
8
>20
>20
0.29
>20
>20
0.31
18
>20
0.33
15
>20
0.36
12
>20
0.38
10
>20
0.41
8
>20
0.43
18
0.45
15
Step 2 Check minimum heat pump low
To install an air-to-water heat pump, the flows shown below must be used
even if step 1 gives a lower flow.
CTC EcoAir 406
0.21 l/s
CTC EcoAir 408
0.27 l/s
CTC EcoAir 510
0.21 l/s
CTC EcoAir 520
0.39 l/s
This building requires:
[l/s]
Step 3 Check whether a volume tank is needed
If the flow is below 0.45 l/s, the system can manage without a CTC VT 80
volume tank. If the system has a high pressure differential, a volume tank
may be required. If the required flow is greater than 0.45 l/s, this accessory
should be installed.
A CTC VT 80 volume tank must be installed to increase the flow in the
system in the following cases:
• If the flow exceeds 0.45 l/s.
• If a mixing valve for an EHS-tank or external peak needs to be installed
and the flow exceeds approx.: 0.35 l/s.
• If the flow in the heating circuit can be closed quickly, e.g. floor heating
with no bypass etc.
A CTC VT 80 volume tank should be installed in the following cases:
• The system volume is less than 20 litres per kW heat pump to achieve
good operation.
Step 4 Dimension the pipeline to the heat pump
The pipe dimensioning between the heat pump and CTC EcoZenith 350
depending on flow and number of metres between the products (single
route).
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...