![CTC Union EcoZenith i350 H Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/ctc-union/ecozenith-i350-h/ecozenith-i350-h_installation-and-maintenance-manual_2693231064.webp)
64
CTC EcoZenith i350
11.4.3
Night reduction in temperature
You use this menu to activate and set a reduction in
the temperature at night. A night reduction means that
you reduce the temperature indoors during scheduled
periods, for example, at night or when you are working.
The value by which the temperature is reduced,
Room
temp reduced °C, is set under Installer/Settings/Heating
circuit.
The value by which the temperature is reduced, Room
temp reduced, is set under Installer/Settings/Heating
circuit/Factory setting: -2°C.
The options are
Off, Day by day or Block. If you select
Off, no reduction is made at all.
Day by day menu
You use this menu to schedule a reduction on the days
of the week. This schedule is repeated every week.
The time set is when you want to have night reduction;
the temperature is normal at other times.
Block
This menu allows you to set a reduction for a few
days during the week, for example, if you are working
elsewhere on weekdays and are at home at weekends.
i
The value by which the temperature is reduced, Room temp reduced
°
C, is set
under Installer/Settings/Heating circuit/Factory setting: -2°C.
i
Reducing a heat pump’s
temperature at night is a comfort
setting which generally does not
reduce energy consumption.
Holiday
Example: On Monday evening at 10 pm the temperature is
reduced to the set night reduction temperature. On Tuesday
morning at 6 am it is raised to normal temperature.
On Sunday at 10 pm, the temperature is reduced by the value
set for Room temp. On Friday at 2 pm the temperature is
increased to the set value again.
22 - 24
-- - --
00 - 06
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
-- - --
1
2
2
Night reduction heat circ.
Weekly program
Day by day
NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
1
2
2
Night reduction heat circ.
Weekly program
Block
NR
Decrease
Sunday 22:00
Increase
Friday 14:00
Decrease
-------- 00:00
Increase
-------- 00:00
Holiday
Holiday period
3
days
You use this option to set the number of days that
you want the set night reduction temperature to be
constantly reduced. For example, if you want to go on
holiday.
You can apply this setting for up to 300 days.
The period starts from the time at which you set this
parameter
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...