X-320M™ User's Manual
Installation and Setup
2.4.7 Logging Tab
X-320M™ can be configured to record data such as wind speed and direction, temperature, and solar
radiation. The logged data is stored in internal non-volatile memory and can be retrieved by entering the
command
http://{X-320M IP address}/log.txt
. For more information on logging, see
Appendix E: Log Files
.
The log is stored in non-volatile flash memory using a circular buffer (old date is over written). 512 kB of
memory space is reserved for logging. Log entries are composed of the following components: 8-byte
header, and 4 bytes for each log feature selected. A log of Wind Speed (4 bytes) and Humidity (4 bytes)
will occupy 16 bytes per entry. Note: Changing the log settings will erase the current log file.
Logging Enabled
When this option is set to
Yes
, X-320M™ will record data as configured on this page. The default
setting for this option is
No
.
Note: This option controls data logging, but not system logging. System logging is always enabled.
Start Time
If a periodic logging interval is specified, logging will occur relative to the start time. For example, if
the start time is 01:00 and the logging rate is 6 hours, logging will occur at 01:00, 07:00, 13:00, and
19:00. Start time is specified in 24-hour time format. The default setting for this field is
01:00.
Xytronix Research & Design, Inc.
Page 47
Figure 2.4g - Logging Tab