Appendix G: Common Sensor Setup Parameters
X-320M™ User's Manual
Make
Model Output
Slope
Offset
Settings
Connections
Davis
7852
N.O. Reed
Switch
in: 0.01
mm: 0.254
0
I/O: Input, Pull-Up,
Increment when input off
Digital Input
Ground
RM
Young
52203 N.O. Reed
Switch
in: 0.00394
mm: 0.1
0
I/O: Input, Pull-Up,
Increment when input off
Digital Input
Ground
Water
Log
H-340 N.O. Reed
Switch
in: 0.01
mm: 0.254
0
I/O: Input, Pull-Up,
Increment when input off
Digital Input
Ground
Met One 360
N.O. Reed
Switch
in: 0.01
mm: 0.254
0
I/O: Input, Pull-Up,
Increment when input off
Digital Input
Ground
Met One 364
N.O. Reed
Switch
in: 0.00394
mm: 0.1
0
I/O: Input, Pull-Up,
Increment when input off
Digital Input
Ground
Temperature
X-320M™ can be used with 1-Wire temperature sensors such as Xytronix X-DTS-U, X-DTS-WM, and X-
DTS-S12. Linear response analog sensors (voltage or current output) may also be used. Non-linear
thermistors are not compatible.
The use of 1-Wire sensors has the advantage of allowing multiple sensors to be installed and frees up
analog ports for other sensor options.
Make
Model
Output
Slope
Offset
Settings
Connections
Xytronix
X-DTS-U
X-DTS-WM
X-DTHS-S12
X-DTS-S12
1-Wire
F: 1.0
C: 0.5555
F: 0
C: 17.778
--
5Vout
Gnd
Data
RM
Young
41382VC
0-5 VDC
C: 20
C: -50
--
5Vref
Agnd
Ain
RM
Young
41382VF
0-5 VDC
F: 40
F: -50
--
5Vref
Agnd
Ain
Radiation shields such as the Davis Instruments 7714 or RM Young 41003 may be required.
The RM Young sensors are often listed as 0-1 VDC output. These sensors have a selectable output
range and can be configured as 0-5 VDC. Please refer to the sensor instruction sheet.