2.4.8 Remote Devices Tab
Remote Device
This option allows you to select which remote device the following settings will apply. You can
configure up to three remote devices.
-
Remote Relay 1-2:
This allows you to select either Remote Relay 1 or Remote Relay 2.
Note: Remote Relay 1 and 2 can be separate remote devices.
-
Remote Analog:
This allows you to receive analog data from another ControlByWeb
devices that features Analog Inputs, such as the X-320, X-320M, or Analog Module. Up to 4
single-ended analog inputs from a device can be read.
IP Address
The IP address of the remote device is entered here. The default value is
192.168.1.15.
TCP Port
The TCP port number used to access the remote device is entered here. This must match the TCP
port (HTTP port) set in the remote device. The valid range is
0
to
65530
. The default port number is
80.
Password
If the remote device requires a password for control, the password must be entered here.