X-320M™ User's Manual
2.4.6 Date/Time Tab
X-320M™ uses the time for logging (a time stamp is included with each logged event). The time is
stored and displayed in 24-hour time format. X-320M™ has a capacitor-backed real-time-clock circuit
that will keep track of time for several days in the event of a power failure.
Current Date/Time
This is the current date and time stored in X-320M™. The time is stored and displayed in 24-hour
format.
Set Time
This drop-down list offers two options for setting the time:
Manually
or
Sync with NTP server
.
The options that follow this field will change based upon how this option is set.
-
Manually
requires the user to enter the time and date.
-
Sync with NTP server
allows the user to set the clock automatically by using an NTP
(Network Time Protocol) server.
Page 42
Xytronix Research & Design, Inc.
Figure 2.4e - Date/Time Tab - Set Time Manually