Section 3: Configuring a Wafer ID Application
In-Sight
®
1700 Series Wafer Reader
26
In all cases, the raw read score of the character string must be higher than the specified
Accept threshold before the checksum will be evaluated (see Section 3.5.7). Then if the
character string passes its checksum, bonus points in increments of 100 and/or 200 are
added to the raw reading score and the read passes. The number of bonus points added
to the raw score depends on the Checksum selected.
When Virtual checksum is selected by itself, the Accept threshold should be increased,
and the Field String & Field Definition should be made as specific as possible to limit the
list of possible characters at each position in the string. These steps will increase reading
reliability in the absence of a mathematical checksum.
SELECTION
DESCRIPTION
Virtual
The Cognex Virtual checksum attempts to validate the read result using multiple reading methods.
If all methods read identical characters at each position in the string, the string passes the Virtual
checksum and 100 points are added to the raw response score.
This checksum should be used by itself only when the character string is known not to contain one
of the other checksums, and then a higher Accept threshold is strongly recommended.
Maximum score: 200 points
Minimum passed score: 100 plus Accept threshold
SEMI
Applies the SEMI-standard checksum and the Cognex Virtual checksum. If the read result passes
the SEMI checksum, 200 points are added to the raw score. If the read result also passes the
Virtual checksum and the results from both checksums agree, an additional 100 points are added
to the score.
The read must pass the SEMI checksum to be successful; if Virtual checksum passes but the
SEMI checksum fails, the entire read will fail.
Maximum score: 400 points
Minimum passed score: 200 plus Accept threshold
SEMI with Virtual
(default)
Applies the SEMI-standard checksum and the Cognex Virtual checksum. If the read result passes
the SEMI checksum, 200 points are added to the raw score. If the read result also passes the
Virtual checksum and the results from both checksums agree, an additional 100 points are added
to the score.
The read must pass both the SEMI and Virtual checksums to be successful; if either checksum
fails, the entire read will fail.
The SEMI with Virtual checksum selection is the most reliable method of validating a character
string containing a SEMI checksum.
Maximum score: 400 points
Minimum passed score: 300 plus Accept threshold
BC 412 with Virtual
Applies the SEMI-standard barcode checksum and the Cognex Virtual checksum. If the read result
passes the BC 412 checksum, 200 points are added to the raw score. If the read result also
passes the Virtual checksum and the results from both checksums agree, an additional 100 points
are added to the score.
The read must pass both the SEMI BC 412 and Virtual checksums to be successful; if either
checksum fails, the entire read will fail.
This selection is typically used when the character string is marked directly below the barcode on
the wafer.
Maximum score: 400 points
Minimum passed score: 300 plus Accept threshold
IBM 412 with Virtual
Applies the IBM barcode checksum and the Cognex Virtual checksum. If the read result passes
the IBM 412 checksum, 200 points are added to the Raw Score. If the read result also passes the
Virtual checksum and the results from both checksums agree, an additional 100 points are added
to the score.
The read must pass both the IBM 412 and Virtual checksums to be successful; if either checksum
fails, the entire read will fail.
This selection is typically only used when the character string is marked directly below the barcode
on the wafer.
Maximum score: 400 points
Minimum passed score: 300 plus Accept threshold
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...