In-Sight 1700/1701 Acquisition Trigger Input Specifications
Table 8-6: Acquisition Trigger Input Specifications
SPECIFICATION
DESCRIPTION
ON 20 to 30V (24V nominal)
VOLTAGE
OFF 0 to 3V (12V nominal threshold)
ON 0.9 to 1.3mA
OFF <150
µ
A
Resistance ~22,000 Ohms
CURRENT
For higher current add external resistor (for example, 2.2k
Ω
, 0.5W for 12mA) across inputs.
DELAY
In-Sight 1700/
In-Sight 1701
250
µ
Sec latency between leading edge of trigger and start of acquisition. Input pulse
should be minimum of 1ms wide.
The acquisition trigger input is opto-isolated. To trigger from an NPN (pull-down) type
photo-detector or PLC output, connect pin 2 (TRG+) to +24V and connect pin 3 (TRG-) to
the output of the detector. When the output turns ON, it pulls TRG- down to 0V, turning
the opto-coupler ON. To trigger from a PNP (pull-up) photo-detector or PLC output,
connect pin 2 (TRG+) to the output of the detector and connect pin 3 (TRG-) to 0V. When
the output turns ON, it pulls TRG+ up to 24V, turning the opto-coupler ON.
Figure 8-2: In-Sight 1700/1701 Acquisition Trigger Input Schematic
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...