In-Sight
®
1700 Series Wafer Reader
Updating the Wafer Reader’s Firmware
125
4
When prompted for
User:
, enter the In-Sight User Name. For example, the default
In-Sight User Name is
admin
.
5
If prompted, enter the In-Sight Password.
6
When logged in, copy the .HTM, .JAR, WafID00.JOB, and .SET files from their
location on the FTP server to the wafer reader by typing
mput
followed by the name
of the file (for example,
mput *.jar
copies the two .JAR files).
7
After all files have been copied, close the FTP prompt.
Once the files have been copied to the wafer reader’s flash memory, load the default job
into the spreadsheet using the PC Host’s Save & Load dialog.