Section 7: Native Mode Commands
In-Sight
®
1700 Series Wafer Reader
86
EV GetWaferFixCol(<WafID>)
EV GetWaferFixTheta(<WafID>)
EV GetWaferNumPassed(<WafID>)
EV GetWaferNumFailed(<WafID>)
EV GetWaferAveScore(<WafID>)
EV GetWaferString(<WafID>)
7.5.5 EV GetWaferAllEx
EV GetWaferAllEx(<WafID>)
Returns all results for the most recent read, and settings for all Configs.
NOTE
The GetWaferAllEx command is only supported on In-Sight 1721/1722 wafer readers with firmware
version 3.20.05 and higher.
Inputs
: WafID
Outputs
: Status Code, # of bytes, BestConfig, Timeout, Order, AcqEnable, NumPassed,
NumFailed, AvgScore, ScoreAs100, Row (Fixture), Col (Fixture), Theta (Fixture), Mark,
Checksum, LightMode, LightPower, Orientation, Row (Region), Col (Region), High
(Region), Wide (Region), Theta (Region), Phi (Region), High (Char), Wide (Char),
FieldString, FieldDef, Color, Accept, Enable, Retry, BComp, Thresh, Optimization,
Passed, String, Score, TryLog, TuneLog, LastRead, NumPassed, NumFailed,
NumTunePassed, NumTuneFailed, AvgScore, High, Wide, Theta, Char (Orc) Value
(Orc), Row, (Orc), Col (Orc)
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...