In-Sight
®
1700 Series Wafer Reader
Section 7: Native Mode Commands
73
SETTING
DESCRIPTION
<Retry>
The tuning behavior.
0 = Disable (default)
1 = Enable
2 = Enable & Apply
<Row>
The row coordinate of the input region or the individual character in a string.
640 x 480 image resolution: 0 – 479
1024 x 768 image resolution: 0 – 767
<Score>
The average raw response scores for all Configs that passed.
0 – 400
<ScoreAs100>
The state of the optional scoring setting for character positions fielded as dashes (-), dots
(.) and spaces. This setting is only available for ‘Chars, SEMI’, ‘Chars, IBM’ and ‘Chars,
Triple’ Marks.
0 = Each character receives a weighted score based on the quality of the read.
1 = Each character automatically scores 100 points.
<Size>
Specifies whether the mark size will be modified during tuning when using the TuneConfig
or TuneCofigEx extended native mode commands.
0 = Disable Size tuning
1 = Enable Size tuning (default)
<State>
The scoring method for character positions fielded as dashes (-), dots (.) and spaces. This
setting is only available for ‘Chars, SEMI’, ‘Chars, IBM’ and ‘Chars, Triple’ Marks.
0 = Each character receives a weighted score based on the quality of the read.
1 = Each character automatically scores 100 points.
NOTE
When the GetWaferAllEx command is issued, the <ScoreAs100> output
returns the <State> value.
<String>
The character results from the read.
alphanumerics (A-Z, 0-9), dashes (-), dots (.), and spaces
<StringLen>
The number of characters in the result string.
0 – 31
<Theta> (CharSize)
The orientation of a 2D symbol or of the characters in a string, as measured in pixels.
<Theta> (Fixture)
The orientation of the fixture.
0 – 359
<Theta> (Region)
The angle of the Config's region.
-179 to 180
<Thresh>
The character threshold setting.
25 to 100 (default = 25)
<Timeout>
The total amount of time (in seconds) to allow for a read, including retries and tuning of
enabled Configs.
0 – 60 (default = 30)
<TryLog>
The Retry status of the Config during the last read.
0 – 99,999
<TuneLog>
The Retry and Tune status of the Config during the last read.
0 – 99,999
<Value>
The raw response score of the specified character in a read string.
0 – 99,999
<WafID>
References the
data structure in spreadsheet cell A4.
<Wide> (CharSize)
The width of a 2D symbol or the average width of the characters in a string, as measured
in pixels.
8 – 480 (default = 20)
<Wide> (Region)
The width of the region (along the X-axis) where the wafer mark is expected to appear in
the field of view.
640 x 480 image resolution: 4 – 640 (default = 500)
1024 x 768 image resolution: 4 – 1024 (default = 600)
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...