Section 3: Configuring a Wafer ID Application
In-Sight
®
1700 Series Wafer Reader
44
This file is saved in the default FTP directory; subdirectories cannot be specified. The
maximum File Name length is 64 characters.
User
A valid User name for the specified host.
Password
A valid password for the User on the specified host.
Output String, Output Score, Output Passed, Output Failed Image
These checkboxes select the results data that will be written out to the HTML file on the
specified host. The following results can be logged:
Output String
Output Score
Pass/fail status of the read
The image, if the read failed
Data is appended to the specified log file. A bitmap file containing the failed image is also
stored on the specified host. A hyperlink to the failed image is included in the log file.
The wafer reader must be Online for data to be appended to the log file. The log file must
be reset manually by deleting, renaming or moving the current .HTM file, or by specifying
a new file name for the log file. An example of the HTML log page, with all outputs
selected, is shown below.
Figure 3-15: HTML Log Page Example
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...