In-Sight
®
1700 Series Wafer Reader
Section 7: Native Mode Commands
95
7.6.9 EV SetConfigColor
EV SetConfigColor(<WafID>,<Config>,<Color>)
Sets the expected color of the wafer mark.
Inputs
: WafID, Config, Color
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGCOLOR(A4,0,1)
1
0
7.6.10 EV SetConfigEnable
EV SetConfigEnable(<WafID>,<Config>,<Enable>)
Specifies whether a Config is enabled or disabled, which determines if the specified
Config will be used during the retry sequence at runtime.
Inputs
: WafID, Config, Enable
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGENABLE(A4,0,1)
1
0
7.6.11 EV SetConfigFieldDef
EV SetConfigFieldDef(<WafID>,<Config>,<”FieldDef”>)
Defines the Field String when Mark specifies a character string or barcode.
NOTE
The FieldDef input must be set off with quotation marks.
Inputs
: WafID, Config, FieldDef
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGFIELDDEF(A4,0,"A=A;B=B")
1
0
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...