Section 5: Running the Job
In-Sight
®
1700 Series Wafer Reader
50
The following sections describe the information displayed in the Run tab.
5.1.1 Online Checkbox
The Online checkbox at the top-right of the Run tab switches the wafer reader between
its Online and Offline modes of operation. When this checkbox is enabled (the default
setting), the wafer reader is “Online”. The File, Setup, and Options tabs are grayed out,
and the following operations are supported:
Output read results data to the log file specified in the Options tab.
Output read results over the serial port when Serial is the selected Output
Destination in the Options tab.
Respond to the protocol’s READ and TUNE commands.
Respond to the camera, network, and serial acquisition Trigger selected in the
Options tab.
Send/receive data to and from the spreadsheet over the network or serial port
using the Input/Output functions.
NOTE
If the Online checkbox is enabled from the browser and a System Offline dialog appears, open the
PC Host and verify that the PC Host’s status bar indicates the wafer reader is Online, then click
OK
to close the dialog.
When the Online checkbox is disabled, the wafer reader is “Offline”. When the wafer
reader is Offline, the following actions are allowed:
Edit settings in the Setup and Options tabs.
Save and open jobs in the File tab.
Manually acquire an image and read the wafer mark using the Read button.
Clear all read results using the Reset Stats button.
Execute Native Mode commands over telnet.
The wafer reader’s Online state is a combination of three independent flags:
Spreadsheet flag – Set directly from the System menu’s Online checkbox in the
In-Sight spreadsheet. This flag can also be controlled by the Online checkbox in
the Startup tab (see Section 6.6). For the browser-based user interface to run
properly, this flag should be enabled.
Native Mode flag – Set from the Online checkbox in the Run tab or from the Set
Online Native Mode command (see Section 7).
Discrete I/O flag – Not used by the wafer reader; enabled by default.
The wafer reader is Online only when all three flags are enabled.
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...