In-Sight
®
1700 Series Wafer Reader
Section 7: Native Mode Commands
81
EV GetConfigRetry(<WafID>,<Config>)
EV GetConfigBComp(<WafID>,<Config>)
EV GetConfigThresh(<WafID>,<Config>)
EV GetConfigOptimization(<WafID>,<Config>)
7.5.2 EV GetConfigResult
EV GetConfigResult(<WafID>,<Config>)
Returns the results of the most recent read performed by the specified Config.
Inputs
: WafID, Config
Outputs
: Status Code, # of bytes, Passed, String, Score, TryLog, TuneLog, LastRead,
NumPassed, NumFailed, NumTunePassed, NumTuneFailed, AvgScore, High, Wide,
Theta, Char (Orc), Value (Orc), Row (Orc), Col (Orc)
Sample Input and Output
EV GETCONFIGRESULT(A4,0)
1
1701
<Result Id="0">
<Passed>1</Passed>
<String>6713H129S6A1</String>
<Score>396</Score>
<TryLog>1</TryLog>
<TuneLog>0</TuneLog>
<LastRead>10</LastRead>
<NumPassed>4</NumPassed>
<NumFailed>0</NumFailed>
<NumTunePassed>0</NumTunePassed>
<NumTuneFailed>0</NumTuneFailed>
<AvgScore>96</AvgScore>
<High>40</High>
<Wide>21</Wide>
<Theta>0</Theta>
<Orc Id="0">
<Char>54</Char>
<Value>96</Value>
<Row>51</Row>
<Col>25</Col>
</Orc>
<Orc Id="1">
<Char>55</Char>
<Value>96</Value>
<Row>51</Row>
<Col>65</Col>
</Orc>
<Orc Id="2">
<Char>49</Char>
<Value>98</Value>
<Row>52</Row>
<Col>105</Col>
</Orc>
<Orc Id="3">
<Char>51</Char>
<Value>97</Value>
<Row>53</Row>
<Col>145</Col>
</Orc>
<Orc Id="4">
<Char>72</Char>
<Value>99</Value>
<Row>53</Row>
<Col>187</Col>
</Orc>
<Orc Id="5">
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...