In-Sight
®
1700 Series Wafer Reader
Section 5: Running the Job
51
5.1.2 Read Log
A record of the most recent read results. This log returns the string, score, and pass/fail
status of each Config that is read or retried.
NOTE
If the wafer reader is Offline, a continuous log is displayed. If the wafer reader is Online, only the
last read results are displayed.
5.1.3 Statistics Window
A statistical record of the read results.
NOTE
Any changes to a Config’s settings will reset the statistics for that Config, but do not change the
overall statistics.
Config
The index of each enabled Config.
Attempts
The number of times the Config has been used during reading.
Passed
The number of times the Config read successfully.
Failed
The number of times the Config failed to read.
Response Avg
The average raw response score of all attempted reads for the Config.
Overall
The cumulative statistics from the results of all reads.
NOTES
■
The Overall statistics are calculated independently of the statistics for the individual Configs.
■
If Retry is enabled from the Setup tab, the Attempts, Passed and Failed statistics do not reflect any
retries.
5.1.4 Read
The
Read
button acquires an image and reads the wafer mark. The String and Score
results are reported to the right. The Read button is grayed out when the Online
checkbox in enabled.
Содержание In-Sight 1721
Страница 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Страница 2: ......
Страница 8: ...In Sight 1700 Series Wafer Reader vi...
Страница 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Страница 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Страница 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Страница 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Страница 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Страница 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...