background image

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies

For the latest technical information about this product, including specifications, dimensions, and wiring, see 

www.BannerEngineering.com

Overview

Figure 1. DF-G1 Model Features

1

Output LED

2

LO/DO Switch

3

RUN/PRG/ADJ Mode Switch

4

Lever Action Fiber Clamp

5

Red Signal Level

6

Green Threshold

7

+/SET/- Rocker Button

Models

Model

Outputs

Connector*

DF-G1-NS-2M

Single NPN

2 m (6.5') cable, 4-wire

DF-G1-PS-2M

Single PNP

DF-G1-NS-Q3

Single NPN

150 mm (6") PVC pigtail, M8 Pico QD

connector, 4-pin

DF-G1-PS-Q3

Single PNP

DF-G1-NS-Q7

Single NPN

Integral M8 Pico QD connector, 4-pin

DF-G1-PS-Q7

Single PNP

* Cordset Options: A model with a QD connector requires a
mating cordset. For 9 m cable, change the suffix 2M to 9M in
the 2 m model number (example, DF-G1-NS-9M). For M12
Euro QD pigtail change the suffix 2M to Q5 in the 2 m model
number (example, DF-G1-NS-Q5).

WARNING: Not To Be Used for Personnel Protection

Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury or death. This
product does NOT include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor
failure or malfunction can cause either an energized or de-energized sensor output condition.

Hookups

NPN Models

PNP Models

Key

 

 

 

 

 

2

3

4

1

 

1 = Brown
2 = White
3 = Blue
4 = Black

For cable options, see 

http://www.bannerengineering.com

DF-G1 - Expert Fiber Amplifier Install Sheet

 

 

P/N 161275 Rev. A

1/6/2012

0 161275

2

Содержание DF-G1 Expert

Страница 1: ...Q7 Single NPN Integral M8 Pico QD connector 4 pin DF G1 PS Q7 Single PNP Cordset Options A model with a QD connector requires a mating cordset For 9 m cable change the suffix 2M to 9M in the 2 m mode...

Страница 2: ...he output is ON when the sensing condition is outside the window SET Rocker Button The SET rocker button is a 3 way button The positions are engaged by rocking the button left right The SET position i...

Страница 3: ...ettings Setting Factory Default Threshold 2026 TEACH Selection Two Point TEACH Response Speed Standard 500 us Offset Percent 10 Auto Thresholds OFF OFF Delay 0 Disabled OFF One Shot 0 Disabled ON Dela...

Страница 4: ...Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to con firm Slide Mode switch to RUN to complete...

Страница 5: ...d signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 3 Dynamic TEACH Light Operate shown SET Button 0 04 seconds Click 0 8 seconds...

Страница 6: ...t Moves sensing window center value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the sensing window center value...

Страница 7: ...ration Remember Manual adjustments are disabled when Auto Thresholds are ON Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset below the presented condition...

Страница 8: ...switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds...

Страница 9: ...bration SET Sensor positions threshold exactly at the presented condition Threshold position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Condition Pres...

Страница 10: ...ed Threshold Error The threshold s cannot be optimized and the sensor s output will stop functioning Cleaning correcting the sensing environment and or a re teach of the sensor is required Specificati...

Отзывы: