TROUBLESHOOTING AND ELECTRICAL SYSTEM: 800 AND 810 GAS
Test Procedures
Page 11-10
2007-2008 XRT 800, 810 and 850 Maintenance and Service Manual
11
6. Hold the hydrometer vertically, ensuring that the float is not contacting the sides of the glass tube. Hold
the hydrometer at eye level and read the scale at the level of electrolyte
(Figure 11-4, Page 11-10)
.
7. Record the reading.
8. Return the electrolyte to the cell from which it was taken. Replace vent cap.
9. Repeat steps 2 through 8 on all cells.
Hydrometer Calibration
Most hydrometers are calibrated to read correctly at 80 °F (27 °C). The readings obtained as described above
must be corrected for temperature. For each 10 °F (5.6 °C) above 80 °F (27 °C), add 0.004 to the reading. For
each 10 °F (5.6 °C) below 80 °F (27 °C), subtract 0.004 from the reading.
Interpreting the Results of the Hydrometer Test
The approximate state of charge can be determined by referring to the following table:
If the difference between the cells is 0.020 or more, the low cell should be suspected. It may require a catch-
up charge or it may be a weak cell. When the variations between cells reach 0.050 or more, the battery should
be replaced.
Figure 11-4 Hydrometer Test
Figure 11-5 Battery Electrolyte Level
SPECIFIC GRAVITY
(TEMPERATURE
CORRECTED)
APPROXIMATE
STATE OF CHARGE
1.250-1.280
100%
1.220-1.240
75%
1.190-1.210
50%
1.160-1.180
25%
4 0
2 0
6 0
8 0
13 00
1.250
1.280
VIEW AT
EYE LEVEL
ELECTROLYTE
LEVEL AT LEAST
1/2-INCH (13 mm)
ABOVE PLATES
OR TO LEVEL
INDICATOR
PLATES
BATTERY
CAP
Содержание 2007 XRT 800
Страница 2: ......
Страница 20: ...1 ...
Страница 30: ...3 ...
Страница 50: ...4 ...
Страница 70: ...5 ...
Страница 114: ...9 ...
Страница 326: ......
Страница 348: ......
Страница 400: ...21 ...
Страница 438: ...23 ...
Страница 456: ...25 ...
Страница 472: ...26 ...
Страница 488: ...27 ...
Страница 500: ...28 ...
Страница 504: ...29 ...
Страница 514: ......
Страница 515: ......