MOTOR (MODEL 5BC59JBS6390)
Motor
Page 26-6
2007-2008 XRT 800, 810 and 850 Maintenance and Service Manual
26
FIELD WINDINGS INSPECTION
Burned or scorched insulation on the field windings indicates the motor has overheated due to overloads or
grounded or shorted coil windings. If the insulation on the field windings is scorched, replace the motor or the
stator shell assembly.
MOTOR COMPONENTS
1. Inspect the insulators (4 and 7) for cracks or other damage
(Figure 26-9, Page 26-8)
.
2. Inspect the brushes (13) for damage or excessive wear. Replace brushes if required.
See following
NOTE.
3. Inspect the brush springs (14)
(Figure 26-9, Page 26-8)
. Replace springs that are discolored from heat
(light gold or blue tinted). Replace springs which apply a force of less than 16 oz.
(Figure 26-7,
Page 26-7)
.
See following CAUTION and NOTE.
CAUT ION
• When checking brush spring tension, do not over-extend the spring. Using excessive force
will damage the spring.
NOTE:
When installing new brushes, remove and replace brushes one at a time. This method ensures the
terminals and brushes will be properly positioned in the rigging. Refer to Motor Assembly for brush
installation.
See Motor Assembly on page 26-10.
When replacing brushes, replace all four brushes. Never replace only two.
Install the brushes in the same rigging 180° apart from each other.
Figure 26-6 Armature Test
COMMUTATOR
ARMATURE CORE
Содержание 2007 XRT 800
Страница 2: ......
Страница 20: ...1 ...
Страница 30: ...3 ...
Страница 50: ...4 ...
Страница 70: ...5 ...
Страница 114: ...9 ...
Страница 326: ......
Страница 348: ......
Страница 400: ...21 ...
Страница 438: ...23 ...
Страница 456: ...25 ...
Страница 472: ...26 ...
Страница 488: ...27 ...
Страница 500: ...28 ...
Страница 504: ...29 ...
Страница 514: ......
Страница 515: ......