IQ DISPLAY MODULE (IQDM) AND IQDM-P DIAGNOSTICS
Programmer Setup
2007-2008 XRT 800, 810 and 850 Maintenance and Service Manual
Page 22-15
22
The following faults can be detected within the handset:
Fault History
This menu displays any faults that have been detected within the handset itself.
Clear Fault History
The
clear fault history
function will erase the history of faults that are stored in the handset.
INFORMATION
This menu selection displays information pertaining to the handset. The information provided in this menu
selection includes model number, serial number, the date the handset was manufactured, the handset soft-
ware version, etc.
CODE NUMBER
TEXT DISPLAYED
9
Time out error detect, no response from
controller
14
Communication error with controller
15
Error in handset
16
Handset does not support this function
17
Serial port overrun error
18
Security lockout on program menu