TROUBLESHOOTING AND ELECTRICAL SYSTEM: 850 GAS
Troubleshooting Guide
Page 12-4
2007-2008 XRT 800, 810 and 850 Maintenance and Service Manual
12
Starter fails to operate.
Neutral lockout switch is in the wrong
position
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Fuse is blown
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 2
Battery is dead
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 1
Starter control circuit is
not operating
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Starter/generator failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 7
Starter solenoid failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 6
Accelerator pedal limit switch failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 5
Key switch failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 4
Neutral lockout limit switch failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 7
Loose or broken wire in starter/generator
circuit
Section 14 – Electrical Components: 850
Gasoline Vehicle
Starter/Generator on page 14-1
Cylinder and/or crankcase flooded with
fuel
Section 16 – Fuel System: Gasoline
Vehicle
Starter/generator does not charge
battery.
Loose or broken wire in the starter/
generator circuit
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 10
Generator field coil is shorted
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 10
Brushes are worn or commutator is dirty
Section 14 – Electrical Components: 850
Gasoline Vehicle
Starter/Generator on page 14-1
Starter/generator belt is loose or slipping
Section 14 – Electrical Components: 850
Gasoline Vehicle
Belt Tension Adjustment on page 14-11
Voltage regulator failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 11
Battery failed
Section 12 – Troubleshooting and
Electrical System: 850 Gas
Test Procedure 1
Troubleshooting Guide continued on next page...
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
Содержание 2007 XRT 800
Страница 2: ......
Страница 20: ...1 ...
Страница 30: ...3 ...
Страница 50: ...4 ...
Страница 70: ...5 ...
Страница 114: ...9 ...
Страница 326: ......
Страница 348: ......
Страница 400: ...21 ...
Страница 438: ...23 ...
Страница 456: ...25 ...
Страница 472: ...26 ...
Страница 488: ...27 ...
Страница 500: ...28 ...
Страница 504: ...29 ...
Страница 514: ......
Страница 515: ......