© 2006 Directed Electronics—all rights reserved
sound. When using the Bitwriter®, the siren can be programmed to sound for any length of time from 1
second to 180 seconds.
2-2 NUISANCE PREVENTION® CIRCUITRY (NPC) ON/OFF:
NPC stops repeated triggering of the same zone.
If one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time
of the third trigger. During that hour, if the system sees a trigger on that zone again, the system resets
the one hour timer. If one hour passes and the zone has not triggered again, the zone is activated and can
trigger the system again. NPC only monitors sensor inputs, and does not bypass the door trigger or the
ignition trigger at any time. If NPC is turned off, the system will respond to repeated triggers on the sensor
inputs and will do so indefinitely. Some states have laws regulating how many times a security system can
trigger before it is considered a nuisance and the vehicle is towed away.
2-3 PROGRESSIVE DOOR TRIGGER ON/OFF:
The system responds to a door trigger input with a progressive
response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full
triggered sequence. The door trigger is still treated as an instant trigger and closing the door quickly will
not prevent full triggered sequence from occurring. If the progressive door trigger is programmed off, the
full siren output will occur the moment the door is opened.
2-4 VALET DISARM PULSE COUNT 1 TO 5 PULSES:
The system can be programmed to count the number of
presses of the valet switch before disarming the security system. The factory default setting is one pulse.
The unit can also be set for two to five pulses.
Ghost Switch option: For added security, the GRAY wire on the two-pin Valet/Program plug can be connected
to any switch in the vehicle that provides a positive (+) momentary pulse.
2-5 DOOR SENSOR BYPASS CHIRP ON/OFF:
This feature controls the error chirp that is generated if the
system is armed with the door trigger active. This is useful in vehicles that have a long dome light delay
after the door has been closed. If the system is armed before the dome light has turned off, the security
system will generate the door trigger error chirp. If this error chirp is not desired, use this feature to disable
the door open error chirp. If the bypass chirp is turned off, no bypass chirp will be generated, even if a
door is accidentally left open.
2-6 IGNITION CONTROLLED DOME LIGHT SUPERVISION ON/OFF:
If turned on, the system will turn on the
dome light for 60 seconds when the ignition is turned off. The optional dome light supervision feature must
be installed as described in the Wire Connection Guide.
2-7 UNLOCK OUTPUT—1,
2
PULSES:
This will program the unlock output to one or two pulses. When the
double pulse unlock feature is turned on, the BLUE door lock harness wire will supply two negative pulses
instead of a single pulse. At the same time, the GREEN door lock harness wire will supply two positive pulses
instead of a single pulse. This makes it possible to directly interface with double pulse vehicles without any