![CLIFFORD MATRIX 70.5X Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/clifford-matrix/70-5x/70-5x_installation-manual_2624432055.webp)
Ford vehicles.
1-8 FORCED PASSIVE ARMING ON/OFF:
To use this feature, passive arming must be selected in Feature 1-1.
When turned on, forced passive arming will ensure that the system will passively arm, even if a zone is left
open or invalid. Forced passive arming occurs one hour after the ignition is turned off.
1-9 AUTOMATIC ENGINE DISABLE (AED) ON/OFF
: AED is a full-time, passive starter disable that works
independently of the security system. When turned on, the orange, ground-when-armed output (H1/1) will
activate 30 seconds after the ignition is turned off. The LED will flash at half its normal rate when the
ignition is turned off to indicate that AED is active and will interrupt the starter in 30 seconds. AED does
not occur in Valet mode and can be bypassed using the emergency override procedure. The remote control
can be used to disarm AED, however, the system must be armed and then disarmed, using the remote
control, to disarm AED.
1-10 ARMED WHILE DRIVING (AWD) ON/OFF:
In the default setting (Armed While Driving), the system
can be armed with the ignition on. When armed, the ground-when-armed is not active and the sensors are
bypassed. The door triggers will remain active.
1-11 CODE HOPPING® ON/OFF:
The system uses a mathematical formula to change its code each time the
remote control and receiver communicate. This makes the group of bits or "word" from the remote control
very long. The longer the word is, the easier it is to block its transmission to the unit. Disabling the Code
Hopping® feature lets the receiver ignore the Code Hopping® part of the transmitted word. As a result, the
unit may have better range with Code Hopping® off.
1-12 HORN OUTPUT PULSED/CONSTANT:
Program for either a pulsed output or a continuous output when
triggered.
1-13 HORN FUNCTION (FULL ALARM ONLY)/SIREN FUNCTION (20mS, 30mS, 40mS, 50mS): Program
for output when the alarm is fully triggered or as the siren (arming/disarming and warnaway and full
trigger with timing options).
1-14 COMFORT CLOSURE—
ON/OFF: The system can be programmed to close the windows when the system is
armed. A 20-second output starts 200mS after the last lock pulse. The Comfort Closure output will be canceled
if the unlock button is pressed. If programmed ON, the lock output wire provides this function.
menu #2 - advanced features
2-1 SIREN DURATION 30/60 SECONDS:
It is possible to program the unit to sound for 30 or 60
seconds during the triggered sequence. Some states have laws regulating how long a security system can
Содержание 70.5X
Страница 4: ......
Страница 31: ... 2006 Directed Electronics all rights reserved 31 Figure A Figure B ...
Страница 68: ... 2006 Directed Electronics all rights reserved 68 relay satellite wiring quick reference guide ...
Страница 69: ......
Страница 70: ...N5501C 12 06 ...