35-3
Cisco Network Modules Hardware Installation Guide
Chapter 35 Connecting Application Performance Assurance Enhanced Network Modules
Application Performance Assurance Enhanced Network Module
Shutting Down and Removing the NME-APA
Enhanced network modules contain hard disks. Removing a module without a graceful shutdown may
result in disk file corruption. Before removing power from the router or starting an online insertion and
removal (OIR) sequence, perform a graceful shutdown by pressing the Reset button on the network
module for less than 1 second, or using an appropriate command-line interface command.
Note
See the
NME-APA User Guide
for details about shutting down the application software on the network
module.
Caution
Do not remove or insert a module with power on unless it is an NME-APA-E3 in a Cisco 3845 Integrated
Services Router.
The application may take 3 minutes to fully shut down. See the
NME-APA User Guide
for instructions
on shutting down the software application on the module.
Caution
Pressing the shutdown button for
more than 4 seconds
initiates
a non-graceful shutdown of the hard disk
which may cause file corruption. After a non-graceful shutdown, the HD and SYS LEDs remain lighted.
SYS
Green
Status of system
ON – Shutdown
complete and the
system is ready for
power off
OFF – Shutdown not
complete
This LED functions
only when a shutdown
is attempted. This LED
is off until the system
shutdown is complete
and the module can be
safely powered off,
Then the LED turns
green.
EN
Green
Status of the network
module
On—Detected by the
host Cisco IOS software
and enabled
Off—Disabled
This LED is off when
the NME-APA card is
plugged into a chassis
that does not support it.
This LED turns on
briefly when detecting a
card type, then goes off
after determining the
card type is not
supported.
Note that a network
module that is shut
down is not disabled.
LED