9
0 sec
When the
("
TA-TC-TD-TAL-TB-FTCI-FTCS, CSP
")
inputs are activated the warning lights will light up.
The status of the security devices
TB
,
FTCI,
FTCS
and
CSP
are always shown on the display.
0 sec
5 sec
0 sec
The segments regarding the command status
(
LED “ON”
=
command active
) and safety status
(
LED “ON”
=
safety device at rest
) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once
999999
has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "
test
" mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices. The warning lights
will activate once, each time a “
TA-TC-TAL-TD-
TB-FTCI-FTCS-CSP
” command is received. In
this mode you can activate serial line
communication using the external program,
connected to the
CSER
connection via cable.
While communication is active dashes will appear
on the display; after 5 seconds of inactivity you
will be moved back to the "
test
" mode. To return
to the normal mode press the button again “
test
”
will appear, then wait for 10 seconds.
Memorising the DIP-SWITCH settings and
displaying the firmware version (e.g. “
0
”)
PRESS PROG
PRESS PROG
PRESS PROG
PRESS PROG
Connect the
programming device
(
CSER
) and activate it.
PRESS PROG
PRESS
PROG
SNS
=
Setting the current sensor:
1 = motor consu 2 amp
2 = motor consu 3 amps
3 = motor consu 3,5 amps
PRESS PROG
10 s after the last modification you will
automatically exit the mode and the
selected values will be saved (eg. 3)
10 seconds after the last modification
you will be automatically moved out
of the mode and the selected values
will be saved (eg. 4)
0 sec
0 sec
0 sec
APL
=
Setting the limited opening space:
1 = 1/3 of the distance of gate 1
2 = half the distance of gate 1
3 = 2/3 of the distance of gate 1
4 = the entire distance of gate 1
0 sec
Each time "
PROG
"
is
pressed
the
number increases
(from 1 to 4).
PRESS
PROG
PRESS
PROG
0 sec
0 sec
PRESS
PROG
Selecting the type of motor
BL1924 = Articulated operator arm
BL3924 = Articulated operator (integrated)
HL2524 = Underground operator
BL224E = Straight arm operator
PRESS
PROG
Each time "
PROG
"
is
pressed
the
number will increase
(from 1 to 3).
0 sec
PRESS
PROG
DISPLAY MODE
Automatic repositioning
If the programmer blocks due to an encoder count error
, after a program-
mer reset
, when one of the motors has been released
or there is a
problem with one of the motors
the warning lights and indicator light will
flash simultaneously for
2 seconds
and will then switch off for
0 seconds
.
After the programmer has been in this condition for
3 minutes
it will (after pre-
flashing for
0 seconds
) automatically move the gate, slowly, to the completely
closed position (2 times as in the programming procedure) in order to recover the
correct position. At this point the programmer will function normally.
To carry out automatic repositioning without waiting for
3 minutes
you may send
a (
TA, TC, TAL
or
TD
) command to the programmer. If a “
TA
” command is given
the positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will
cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another
3 minutes
,
press the “
PROG
” or “
TB
” button.
Using the
PROG
button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "
test
" mode;
- set the limited opening distance;
- set the current sensor level;
- selecting the type of motor.