Service Mode > COPIER > OPTION > CUSTOM
Service Mode > COPIER > OPTION > CUSTOM
COPIER > OPTION > CUSTOM
AC-FREQ
Setting of frequency of AC power
Lv.2 Details
Although power frequency is judged for power control with the
machine, it might be judged incorrectly depending on power
circumstance at the installation location.
At left side column, the power frequency (50 Hz/60 Hz) which the DC
Controller judged at power-on is displayed.
In the case that the power frequency is not matched with the one
at the installation location, set the AC power frequency at right side
column.
Use case
When the breaker is frequently tripped during operation
Adj/set/operate method 1) Select the right side column.
2) Enter the setting value, and then press OK key.
Display/adj/set range
Left side: 0 to 1
0: 50 Hz, 1: 60 Hz
Right side: 0 to 2
0: Judged frequency is used, 1: 50 Hz, 2: 60 Hz
Default value
0