2
2
2-203
2-203
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Procedures to Restore Backup Data
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Procedures to Restore Backup Data
6) Saving backup data
Upon the backup data transferred to the PC, enter an appropriate file name and click [OK]
to save the backup data on the PC.
When the file is successfully saved, click [OK] button, and then click [Return to Menu]
button.
F-2-284
F-2-285
■
Procedures to Restore Backup Data
1) Connecting to the device
Connect the device using SST by following step 1 to step 4 of the Procedure for backing up
the MEAP application area using SST.
2) Restoring backup file
Click [Upload Data] button and select the data backed up in the previous step (Meapback.
bin) to click [Start Restoring Data]. Note that the data backed up in a different version
cannot be restored.
3) Transferring Data
When the data is successfully transferred, click the [OK] button shown on the screen. To
continue other jobs, click [Return to Menu] button.
4) Turn off and on the main power switch of the device to gain access in SMS to check that
MEAP applications are surely restored.
5) Restore the backup data and setting saved. Note that the user information of the local
device is included in the backup data, thus does not need to be restored.
F-2-286
F-2-287
Содержание imageRUNNER ADVANCE 6055 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...