<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the Fixing Assembly")
2. Remove the Fixing Assembly. (Refer to page 4-176)
<Procedure>
1) Clean the Fixing Inlet Guide with lint-free paper moistened with alcohol.
2)Clean the Fixing Right Stay, Dowel, Dowel Holder with lint-free paper moistened with
alcohol.
F-4-312
3) Remove the Fixing Inlet Guide Unit.
• 1 Connector
• 2 Wire Saddles
• 1 Harness Guide
• 2 Screws
CAUTION:
When removing the Fixing Inlet Guide Unit, be careful no to turn the 2 Adjustment
Screws.
F-4-313
x3
F-4-314