
2
2
2-200
2-200
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Outline
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Outline
Initializing the Password
■
Outline
When a user forgets the password to log in to SMS, initialize it to the default value of
“MeapSmsLogin” using the switch license for initializing passwords. Follow the steps below:
■
Procedure to initialize the SMS login password
1) Get the switch license for initializing the password.
Request the support of the regional headquarters of the Canon for switch license for
initializing the password presenting the device serial number.
2) Click [Login] button leaving Password field blank or entering incorrect password. The
Return to install Password Settings area appears. Click [Browse..] button and select the
switch license file prepared in advance.
3) When you click [Initialize] button, the confirmation message appears. Click [OK] button.
Then Login page opens. Enter the default password 'MeapSmsLogin' to log in. The
password is case-sensitive.
Note:
If you click [Cancel] button, the Login page opens without initializing the password.
F-2-281
Backup of the MEAP Application Area and Recovery of
the Backup Data Using SST
■
Outline
When replacing or formatting the hard disk drive, the data in the MEAP application area
needs to be temporarily saved to your PC.
This chapter describes information on backing up the data in the MEAP application area and
recovering the backup data.
In the case of MEAP-installed devices, the application is license-managed, so the application
needs to be reinstalled and reconfigured when replacing or formatting the hard disk drive.
In that case, a license for reinstallation needs to be downloaded and the customer data and
configuration information need to be recovered, and these procedures pose heavy burdens
on the service technician.
The area used for the MEAP application can be easily saved/recovered by using the backup
function of SST (Service Support Tool).
This greatly reduces the work burden on the service technician.
Please note that the application cannot be illegally copied because the backup data can be
recovered only when the iR device has the same serial number.
WARNING:
You must not perform any other work (including checking operation) until the HDD has
been backed up. This arrangement is to prevent a mismatch of MEAP counter readings
and the HDD contents, and any fault in operation arising as the result of failure to
observe this will not be covered by the guarantee of operation.
Note:
The application that is installed with a reusable license can be reinstalled by using the
same license.
Содержание imageRUNNER ADVANCE 6055 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...