E002 -0001
-05
Title
Fixing Assembly temperature rise error
Remedy
1. Check the connection of the Fixing Main Thermistor
(THM1). -> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor. ->
Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
6. Replace the Relay PCB (PCB5).
Description • Temperature of the Fixing Main Thermistor (THM1) does
not reach 100 degC although 12 seconds have passed
since it reached above 70 degC after starting the Fixing
Roller temperature control.
• Temperature of the Fixing Main Thermistor does not reach
130 degC although 12 seconds have passed since it
reached above 100 degC after starting the Fixing Roller
temperature control.
• Temperature of the Fixing Main Thermistor does not reach
150 degC although 20 seconds have passed since it
reached above 130 degC after starting the Fixing Roller
temperature conrtol.
E002 -0010
-05
Title
Fixing Assembly temperature rise error
Remedy
Clear the error.
Description Turning OFF and then ON the power without clearing the
error.
E003 -0000
-05
Title
Fixing Assembly temperature decrease error
Remedy
1. Check the connection of the Fixing Main Thermistor
(THM1). -> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor. ->
Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
6. Replace the Relay PCB (PCB5).
Description The Fixing Main Thermistor (THM1) detects 70 degC or lower
for 2 seconds or longer although the temperature reached
above 100 degC after starting the Fixing Roller temperature
control.
E003 -0010
-05
Title
Fixing Assembly temperature decrease error
Remedy
Clear the error.
Description Turning OFF and then ON the power without clearing the
error.
E
Code
Detail
Code
Location
Item
Description
E004 -0010
-05
Title
Fixing Power Supply error
Remedy
Clear the error.
Description Turning OFF and then ON the power without clearing the
error.
E004 -0205
-05
Title
Fixing Power Supply error
Remedy
1. Check the harness of the Fixing Main Thermistor (THM1) in
the Fixing Assembly.
2. Check the connection of the harness of the Fixing
Assembly on the host machine side.
3. Replace the Main Driver PCB (PCB2).
Description Detect that the Fixing Main Thermistor Unit is not connected.
E005 -0000
-05
Title
Fixing Cleaning Web absent error
Remedy
1. Replace the Fixing Cleaning Web.
2. Replace the Fixing Cleaning Web Level Sensor (PS45).
3. Replace the DC Controller PCB (PCB1).
After executing the measures, clear the Fixing Cleaning
Web counter (COPIER > COUNTER > MISC > FIXWEB).
Description After noticing the Fixing Cleaning Web absent, the web was
pulled out 2000 times.
E005 -0001
-05
Title
Error in Fixing Cleaning Web Drive Solenoid connection
Remedy
1. Check the connection of the Connector.
2. Replace the Fixing Cleaning Web Drive Solenoid (SL9).
Description Connection of the Fixing Cleaning Web Drive Solenoid (SL9)
is not detected when the power is turned ON.
E005 -0010
-05
Title
Fixing Cleaning Web error
Remedy
Clear the error.
Description Turning OFF and then ON the power without clearing the
error.
E012 -0001
-05
Title
Drum Motor (M1) error
Remedy
1. Check the connection of the Main Driver PCB (PCB2) and
the Drum Motor (M1).
Motor side: J2138, PCB side: J109
2. Check the voltage of the Drum Motor (M1) J2151.
If voltage is 0V, check the connection of the Relay PCB
J520.
3. Replace the Drum Motor (M1).
4. Check the gear of the Drum Drive Shaft.
If the load is too much, replace the Process Unit and the
Drum Drive Unit (Shaft).
5. Replace the Main Driver PCB (PCB2).
6. Replace the DC Controller PCB (PCB1).
Description Lock error of the Drum Motor (M1).
Содержание imageRUNNER ADVANCE 6055 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...