Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
6. Touch the numeric button [1] on the control panel (the setting value is changed to 1) and
touch the [OK] button. (The data is reflected to the setting value field.)
CAUTION:
The following settings i.e. RGW-PORT and RGW-ADR in Service mode must not be
change unless there are specific instructions to do so.
Changing these values will cause error in communication with UGW.
F-2-327
F-2-326
7. Select [COM-TEST] and then touch [OK].
This initiates the communication test between the device and the UGW.
If the communication is successful, “OK!” is displayed. If “NG!” (failed) appears, refer to the
“Troubleshooting“ and repeat until “OK!” is displayed.
NOTE:
The communication results with UGW can be distinguished by referring to the COM-
LOG. By performing the communication test with UGW, E-RDS acquires schedule
information and starts monitoring and meter reads operation.
F-2-328
F-2-329