2
2
2-201
2-201
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Requirements for Backup Using the SST
Technology > MEAP > Backup of the MEAP Application Area and Recovery of the Backup Data Using SST > Requirements for Backup Using the SST
■
Backup Item Automatically Copied
●
The following data are backed up using SST:
The following data are backed up (saved as Meapbackup.bin) using SST.
• MEAP applications.
• Setup data generated by MEAP applications (Note that image data stored in BOX will not
be saved for MEAP applications using BOX function).
• User information data registered for local device authentication in SSO-H
• SMS password
●
Data backed up using SST in the case of iR-ADV devices
In the case of iR-ADV devices, menus are implemented as MEAP application. Therefore the
following items can be also backed up (stored as Meapbackup.bin).
• Setting items of each menu in the main menu ( Copy, Scan and Send, Fax, Scan and
Store, Access Stored Files, Fax/I-Fax Inbox, ).
• Favorite settings
• Default settings
• Settings of option shortcuts
• Previous settings
• Settings of quick menu
• Button size information
• Wallpaper settings
• Quick menu button information
• Restrict quick menu use
■
Requirements for Backup Using the SST
The following conditions must be met for use of the function:
1) Device Firmware Version
Device Firmware Version for SST (Ver4.2x)
Boot ROM
System
SST
iR-ADV C2030/C2020 series
Boot ROM is not
equipped.
Already supported
since the 1st
version.
The version supporting
the corresponding
devices.
imageRUNNER ADVANCE
series other than iR-ADV
C2030/C2020 series
Already supported
since the 1st
version.
Already supported
since the 1st
version.
The version supporting
the corresponding
devices.
2) SST Version
Version 4.2.x or later. An earlier version will not permit the use of the function. If needed,
upgrade the SST.
3) Space for backup
To back up the HDD of the iR, the PC must have approx 1024MB of free space at
maximum. Sizes of backup files depend on actual data capacities to be backed up.
T-2-109
Содержание imageRUNNER ADVANCE 6055 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...