7
7
7-9
7-9
Error Code > Error Code > Error Code Details > E000 to E069
Error Code > Error Code > Error Code Details > E000 to E069
E
Code
Detail
Code
Location
Item
Description
E060 -0002
-05
Title
Primary Charging Shutter HP close error
Remedy
1. Check the position of the Primary Charging Shutter and the
Cleaning Pad.
1-A. In the case that the Primary Charging Shutter and the
Cleaning Pad fail to operate (stopped at HP at front side)
1-A-1. Check the connection of the Primary Charging Wire
Cleaning Motor (M6).
Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iR-
ADV 6xxx) (relay), PCB side: J3177 (relay), J107
(Main Driver PCB (PCB2))
1-A-2. Replace the Primary Charging Wire Cleaning Motor
(M6).
1-B. In the case that the Primary Charging Shutter and the
Cleaning Pad are stopped at rear side (close operation
position)
1-B-1. Check the connection of the Primary Charging
Shutter Sensor (PS94).
Sensor side: J2029, J3089 (relay), PCB side: J3088
(relay), J114 (Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging Shutter Sensor
(PS94).
1-C. In the case that the Primary Charging Shutter and the
Cleaning Pad are stopped along the way
1-C-1. Check the loosening of screw on the Slider Pin and
abrasion of the pin. Tighten the screw or replace the
Slider Pin.
1-C-2. Replace the Primary Charging Assembly.
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
Description The Primary Charging Shutter Sensor (PS94) detects that the
shutter is closed although it is moved to the open position.
E
Code
Detail
Code
Location
Item
Description
E061 -0001
-05
Title
Potential control error (VL)
Remedy
1. Check the connection of the Pre-exposure LED (connector
connection, open circuit, the caught cable).
2. Check the installation of the Primary Charging Assembly
(connector connection, open circuit, the caught cable).
3. Check the fixation state of the Drum and the Drum Shaft.
(Check if the drum fixation cylinder is properly installed.)
4. Check if the Dustproof Glass is soiled. If necessary, clean
it.
5. Check the installation of the Laser Scanner Unit (connector
connection, open circuit, the caught cable).
6. Check the installation of the Primary Charging High Voltage
PCB (PCB11), and its connection (connector connection,
open circuit, the caught cable).
7. Check the installation of the Potential Sensor (connector
connection, open circuit, the caught cable).
8. Check the installation of the Drum Motor (M1), and its
connection (connector connection, open circuit, the caught
cable).
9. Replace the parts.
• Primary Charging Assembly
• Laser Scanner Unit
• Potential Sensor
• Primary Charging High Voltage PCB (PCB11)
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
Description The measured value in the dark area (VL) d/-30V or
higher than the target potential at potential control.
NOTE:
If the difference is somewhere b/-10V
and less than 30V, alarm is indicated.
Содержание imageRUNNER ADVANCE 6055 Series
Страница 4: ...Blank Page ...
Страница 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Страница 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Страница 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...