1
1
.
.
O
O
v
v
e
e
r
r
v
v
i
i
e
e
w
w
- 14 -
Figure 0-1 Channels in 5 GHz band
*1
: DFS (Dynamic Frequency Selection): A function that operates when a military or weather radar signal is detected whereby the access point changes to
another channel, relinquishing the original channel to the radar signal. Required by W53 and W56. Channel switching requires several tens of seconds to
complete.
*2
: TPC (Transmission Power Control): A function that automatically adjust the waveform output as necessary in order to maintain communication between
the access point and the wireless terminal device.
*3
: Taiwan W53 is exceptional in not requiring DFS.
*4
: The CXDI-80C product specifications do not support DFS, so channels W53 and W56 (which require DFS) are not available for use.
*5
: South Korea allows use of W58 up to channel 161.
*6
: Refer to the following regarding channel combinations that can be used for channel bonding with HT40 (40 MHz).
Reference: Notes on radio frequency, and Available areas and restrictions are listed in the User’s Manual of the CXDI-80C Wireless.
As indicated above, in the 5 GHz band the channels in the same frequency band that can be used without interference when HT40 is used are as
follows: 2 channels in HT20 and 1 channel in HT40 for W52, 3 channels in HT20 and 1 channel in HT40 for W58.
Primary channel
Secondary
channel offset
Secondary
channel
Channels within the same frequency band
that can be used simultaneously without
interference
36CH above 40CH
HT20:44,48CH
HT40:44-48CH
40CH below 36CH
44CH above 48CH
HT20:36,40CH
HT40:36-40CH
48CH below 44CH
Not listed as W53 is not supported.
Not listed as W56 is not supported.
149CH above 153CH
HT20:157,161,165CH
HT40:157-161CH
153CH below 149CH
157CH above 161CH
HT20:149,153,165CH
HT40:149-153CH
161CH below 157CH
Содержание CXDI-80C
Страница 6: ...Note These measurements are only guidelines ...
Страница 10: ...1 1 O Ov ve er rv vi ie ew w 2 2 System diagram ...
Страница 48: ...2 Installation procedures 15 4 Handle unit option Corner pads Outer box Inner box ...
Страница 53: ...2 Installation procedures 20 7 Installation 7 1 Connections to the units 7 1 1 System connection diagram ...
Страница 82: ...2 Installation procedures 49 4 Battery Weight 0 25 kg Dimensional unit mm Dimensional tolerance 1 Scale 1 N ...
Страница 133: ...Rev 01 CONTENTS Detector unit 1 X ray interface box unit 2 Wiring unit 4 Handle unit 6 ...
Страница 134: ...Rev 01 Detector unit KEY NO PARTS NO Q TY DESCRIPTION MEMO 1 BA5 1230 000 2 Battery Connector Pad 1 1 ...