General Troubleshooting Procedures
81
Note
The CPE also gets its IP address from the Radius Server. Therefore, the IP address must be
available in the Radius Server.
To reset the CPE to factory defaults, perform the following steps:
1. Execute a short power cycle of the CPE. At the power source, you must do a simultaneous power
OFF and power ON.
2. Using a PC, open a web browser and access the default IP address
192.254.1.1
to view the Radio
Recovery Console page for the CPE (for example, as shown in
Figure 61
).
Figure 61:
The Radio Recovery Console page - CPE
Table 10
lists and describes the parameters required for resetting the CPE to factory defaults.
Table 10: Parameters in the Recovery Image Console page for CPE
Parameter
Description
Boot Selection
Reset Configuration
Resets the entire CPE configuration back to default
settings. This implies that you must reconfigure all the
parameters for the CPE, including the IP address.
Note: This is an option that you can use in case of loss of
the IP address.
Reset Configuration Except IP
Management
Resets the CPE configuration parameters except for the
IP address.
This is an option that can be used to reconfigure a CPE
from scratch, but it will not reset the IP address.
Therefore, you can use the web interface or SNMP to
replay a saved configuration if needed.
When you select this option, the Radio Recover Console
page appears with the following details: