General Troubleshooting Procedures
70
Figure 53:
Cable to B1000/LPU wiring
Details of pin numbers, wire colors (when using the recommended cable), and power supply polarities
are given in
Table 4
.
Table 4: Details of pin number, wire color, and DC polarity
Pin number
Wire color
DC Polarity
Notes
1
Brown
Positive (+ve)
2
Green
Positive (+ve)
3
White
Negative (-ve)
Negative pins are closest to the plug
latch.
4
Yellow
Negative (-ve)
Power supply connection (type B)
Ensure to review the
cable testing
section before making the connections to the power supply.
The connection between the four wires of the drop cable and the two wires of the power supply must be
made, as shown in
Figure 54
.
In
Figure 54
, two examples are shown using a terminal block and using crimps. Cambium Networks do
not supply this connector. The installer must use any similar suitable means that fits the site installation.
Figure 54:
Cable to PSU wiring, terminal block (left), crimps (right)
Details of wire colors (when using the recommended cable) and power supply polarities are given in
Table 5
.