Operational Procedures for BTS
45
When the Enable Reboot check box is selected, the BTS reboots. All the registered CPEs get
disconnected for at least two minutes before they reconnect and register back with the BTS. Some CPEs
may take a longer period to reconnect depending on the range.
Resetting BTS to factory default configuration - Reboot
required
The Configuration tab on the Tools page of the B1000 UI allows you to reset the BTS to factory default
settings. Using the B1000 UI, you can perform the following configurations:
l
Reset the BTS configuration to factory defaults with no change to the local management IP
address, as described
here
.
l
Reset the BTS configuration to factory defaults including the local management IP address, as
described
here
.
Reset BTS to factory defaults with no change to the IP address
To reset the BTS to factory defaults with no changes to the IP address, perform the following steps:
1. From the main B1000 dashboard page, navigate to Tools > Configuration.
The Configuration page appears. If the Local Management Access parameter is ticked, then all the
BTS configurations are reset to factory defaults except for the local management IP address.
2. Select the Enable Reboot check box.
A warning message appears as shown in
Figure 34
. This warning message indicates that a reboot
is necessary to apply the configuration change. The BTS then reboots.
Figure 34:
BTS factory defaults specific parameters
It is necessary to reconfigure the main parameters (as listed in
Table 1
) for the BTS to reconnect to
all the CPEs.
When the reconfiguration of parameters is done, all the registered CPEs must reconnect and
register back with the BTS. This operation may take several minutes to complete. Some CPEs may
take a longer period to reconnect depending on the range.
Reset BTS to factory defaults including the IP address
To reset the BTS to factory defaults including the IP address, perform the following steps:
Содержание cnWave 5G Fixed
Страница 1: ...OPERATION AND TROUBLESHOOTING GUIDE cnWave 5G Fixed System Release 3 0...
Страница 64: ......
Страница 75: ...General Troubleshooting Procedures 75 Figure 57 BTS Data cable troubleshooting Part 2...
Страница 78: ...General Troubleshooting Procedures 78 Figure 59 BTS Data cable Resistance checking...