Operational Procedures for BTS
35
Figure 24:
User account parameters in the Management page
The changes are effective, immediately, with no impact on the operation of the system. However,
any change made to the user accounts and SNMP relationships affects the SNMP management and
the security of the system (to some extent). The changes are effective on logging back into the
system if you are using the web interface.
Modifying the BTS operation frequency – No reboot
required
The Systems page in the B1000 UI allows you to modify the operating frequency (in MHz) of the radio
bearer.
Perform the following steps to modify the frequency specific parameter:
1. From the main B1000 dashboard page, navigate to System > Radio.
The Radio page appears.
For information on how to log on to the B1000 UI, refer to the
Accessing the B1000 UI
section.
2. In the Frequency text box, check and modify the value of the operating frequency (in MHz) for the
BTS.
For more information about this parameter, refer to the
cnWave™ 5G Fixed Configuration Guide.
When you change the value of this parameter, the Save button at the top right corner is
highlighted (in green color). This indicates that it is necessary to save or apply the configuration
change that you made in the Frequency text box.
Even though a reboot of the system is not required, the CPEs must have the new frequency in their
scan frequency list. Otherwise, CPEs will not connect to the BTS. All the registered CPEs will get
disconnected for a short time before they reconnect and re-register to the BTS. It may take longer