Operational Procedures for BTS
44
Changing the bandwidth - Reboot required
The Radio page in the B1000 UI allows you to modify or change the bandwidth (in MHz) of the radio
channel spacing.
Perform the following steps to modify the parameter specific to bandwidth:
1. From the main B1000 dashboard page, navigate to System > Radio.
The Radio page appears.
For information on how to log on to the B1000 UI, refer to the
Accessing the B1000 UI
section.
2. In the Bandwidth field, select the required value(in MHz).
When you change the bandwidth value, a warning message appears. This warning message
indicates that a reboot is necessary to apply the configuration change.
When the Enable Reboot check box is selected, the BTS reboots. All the registered CPEs get
disconnected for at least two minutes before they reconnect and register back with the BTS. Some
CPEs may take a longer period to reconnect depending on the range.
Changing the Uplink Tx Power initial or continuous
control – Reboot required
The Radio page in the B1000 UI allows you to change the uplink (UL) initial or continuous transmit power
control. This action allows you to:
l
reach the BTS target receive power before starting transmission and
l
keep the transmit power control constant, for CPEs, during a session and use the initial transmit
power control level, respectively.
If the UL Tx Power Initial Adjust and the UL Tx Power Continuous Adjust parameters in the Radio page
are set to Disabled, the CPE uses its configured maximum transmit power.
Perform the following steps to change the parameters specific to UL Tx power initial or continuous
control:
1. From the main B1000 dashboard page, navigate to System > Radio.
The Radio page appears.
For information on how to log on to the B1000 UI, refer to the
Accessing the B1000 UI
section.
2. Set the following parameters to either Disabled or Enabled:
l
UL Tx Power Initial Adjust, which determines the initial power adjust mode of CPEs.
l
UL Tx Power Continuous Adjust, which determines the continuous power adjust mode of
CPEs.
For more information about these parameters, refer to the
cnWave™ 5G Fixed Configuration
Guide.
When you change the uplink Tx power initial or continuous control value, a warning message appears.
This warning message indicates that a reboot is necessary to apply the configuration change.