2439.3737
1/2/1 Down None None None None No 1 0 cc4e.
2439.3715
1/2/2 Down None None None None No 1 0 cc4e.
2439.3719
1/2/3 Down None None None None No 1 0 cc4e.
2439.371d
1/2/4:1 Up Forward Full 10G None No 1 0 cc4e.
2439.3721
1/2/4:2 Up Forward Full 10G None No 1 0 cc4e.
2439.3722
1/2/4:3 Up Forward Full 10G None No 1 0 cc4e.
2439.3723
1/2/4:4 Up Forward Full 10G None No 1 0 cc4e.
2439.3724
1/2/5 Down None None None None No 1 0 cc4e.
2439.3725
1/2/6 Down None None None None No 1 0 cc4e.
2439.3729
mgmt1 Up None Full 1G None No None 0 cc4e.2439.3700
The following example configures names for port 1/2/4 sub-ports.
device> enable
device# configure terminal
device(config)# interface ethernet 1/2/4:1
device(config-if-e10000-1/2/2:1)# port-name subport1
device(config-if-e10000-1/2/2:1)# interface ethernet 1/2/4:2
device(config-if-e10000-1/2/2:2)# port-name subport2
device(config-if-e10000-1/2/2:2)# interface ethernet 1/2/4:3
device(config-if-e10000-1/2/2:3)# port-name subport3
device(config-if-e10000-1/2/2:3)# interface ethernet 1/2/4:4
device(config-if-e10000-1/2/2:4)# port-name subport4
device(config-if-e10000-1/2/2:4)# end
device(config)# end
device# end
device>
Removing breakout configuration
Use the
no breakout
command as described to remove 40 Gbps breakout configuration.
Removing 4X10 Gbps sub-ports and restoring the original 40 Gbps port requires the same steps as
configuring breakout.
Enter the
no breakout
command for an individual port or port range as shown in the following
examples. However, for the restored 40 Gbps port configuration to take effect, you must also execute
the
write memory
command and then use the
reload
command to update the unit's configuration.
Removing breakout configuration
FastIron Ethernet Switch Administration Guide
381
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...