Examples
The following example configures the sysmon options for fabric adaptor links:
Brocade(config)# sysmon fa link threshold 3 7
Brocade(config)# sysmon fa link action syslog
Brocade(config)# sysmon fa link log-backoff 15
System monitoring for Cross Bar
On FSX devices, errors typically detected in the cross bar include:
• Bad (IP) headers
• Bad length errors
• Reformat errors
Besides the error count, sysmon also checks for connectivity of SFM/XBAR links. This happens at the
interval defined by the sysmon-timer command generally or specifically for cross bar.
Use the following commands to configure and display the statistics of cross bar or switch fabric module:
•
sysmon xbar error-count
on page 273
•
sysmon xbar link
on page 274
•
show sysmon logs
on page 278
•
show sysmon counters
on page 278
•
show sysmon config
on page 282
•
show sysmon system sfm
on page 283
sysmon xbar error-count
Configures system monitoring for cross bar errors. The
no
form of this command resets the parameters
to default values.
Syntax
sysmon xbar error-count
{
threshold
events polling-interval
|
log-backoff
value
|
action
{
none
|
syslog
} }
no sysmon xbar error-count
Parameters
threshold
Defines the failure threshold for the cross bar error-count event. The threshold is defined as
N/W, where N is the number of events, and W is the number of consecutive polling periods.
When the threshold is reached, actions configured for this event type will take place. Note
that a threshold of 1/W implies that there is no threshold, and no event will be triggered.
events
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
polling-interval
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
log-backoff
System monitoring for Cross Bar
FastIron Ethernet Switch Administration Guide
273
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...