To enable optical monitoring on a specific port, use the following command.
device(config)#interface ethernet 1/1
device(config-if-e10000-1/1)#optical-monitor
To enable optical monitoring on a range of ports, use the following command.
device(config)#interface ethernet 1/1 to 1/2
device(config-mif-e10000-1/1-1/2)#optical-monitor
Syntax:
[no] optical-monitor
Use the
no
form of the command to disable digital optical monitoring.
Setting the alarm interval
You can optionally change the interval between which alarms and warning messages are sent. For all
Brocade devices except the ICX 6650, the default interval is three minutes. The minimum and default
interval for the ICX 6650 is eight minutes and a value of one through seven minutes generates an error
message. To change the interval, use the following command.
device(config)#interface ethernet 1/1 to 1/2
device(config-mif-e10000-1/1-1/2)#optical-monitor 10
Syntax:
[no] optical-monitor
[
alarm-interval
]
For
alarm-interval
, enter a value between 1 and 65535. For the ICX 6650 enter a value between 8 and
65535. Enter 0 to disable alarms and warning messages.
NOTE
The commands
no optical-monitor
and
optical-monitor 0
perform the same function. That is, they
both disable digital optical monitoring.
Displaying information about installed media
Use the
show media
,
show media slot
, and
show media ethernet
commands to obtain information
about the media devices installed per device, per slot, and per port. The results displayed from these
commands provide the Type, Vendor, Part number, Version and Serial number of the SFP, SFP+, or
XFP optical device installed in the port. If there is no SFP, SFP+, or XFP optical device installed in a
port, the "Type" field will display "EMPTY".
On ICX 6430 and ICX 6450 devices, 1G copper ports will always be shown with the type as 1G M-C
(Gig-Copper), even if the ports are not connected.
Use the
show media
command to obtain information about the media devices installed in a device.
device# show media
Port 1/1/1: Type : 1G M-C (Gig-Copper)
Port 1/1/2: Type : 1G M-C (Gig-Copper)
Port 1/1/3: Type : 1G M-C (Gig-Copper)
Port 1/1/4: Type : 1G M-C (Gig-Copper)
Port 1/1/5: Type : 1G M-C (Gig-Copper)
Port 1/1/6: Type : 1G M-C (Gig-Copper)
Port 1/1/7: Type : 1G M-C (Gig-Copper)
Port 1/1/8: Type : 1G M-C (Gig-Copper)
Port 1/1/9: Type : 1G M-C (Gig-Copper)
Port 1/1/10: Type : 1G M-C (Gig-Copper)
Port 1/1/11: Type : 1G M-C (Gig-Copper)
Port 1/1/12: Type : 1G M-C (Gig-Copper)
Port 1/1/13: Type : 1G M-C (Gig-Copper)
Port 1/1/14: Type : 1G M-C (Gig-Copper)
Setting the alarm interval
FastIron Ethernet Switch Administration Guide
221
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...