The following example displays the error events that sysmon has recorded for the fabric adaptor 0.
Brocade# show sysmon counters fa error 0
Sysmon error detected on: SLOT 1, FA 0(number of times)
****PUMA Device 0 VOQUnit0 error detect
Set 0 EnQ Drop detect = 0
Set 1 EnQ Drop detect = 0
Set 2 EnQ Drop detect = 0
Set 3 EnQ Drop detect = 0
tail drop detect = 0 filter drop detect = 0, ecc drop detect = 0
****PUMA Device 0 VOQUnit1 error detect
Set 0 EnQ Drop detect = 0
Set 1 EnQ Drop detect = 0
Set 2 EnQ Drop detect = 0
Set 3 EnQ Drop detect = 0
tail drop detect = 0 filter drop detect = 0, ecc drop detect = 0
****PUMA Device 0 CRX error detect
CRC detect = 0, Lost SOP.EOP detect = 0, no egress Buf detect = 0
fifo full detect = 0, UC congest detect = 0, MC congest detect = 0
bad buf alloc detect = 0, e2e drop detect = 0
The following example shows the crossbar errors for the switch fabric module 0.
Brocade# show sysmon counters xbar error 0
Sysmon SFM 1 xbar 0 HG.link Rx error detected (number of times)
HG.link BadLen BadHeader ReformatErr
0 0 0 0
1 0 0 0
2 0 1 0
3 0 0 0
4 0 0 0
5 0 0 0
6 0 0 0
7 0 0 0
8 0 0 0
9 0 0 0
10 0 0 0
11 0 0 0
The following example displays the cross bar link errors for the SFM module 0.
Brocade# show sysmon counters xbar link 0
Sysmon SFM 0 xbar 1 HG.link NO-SYNC detected (number of times)
HG.link NO-SYNC
0 0
1 0
2 0
3 0
4 0
5 1757
6 0
7 0
8 0
9 0
10 0
11 0
The following example displays the error counter for the specified packet processor 0.
Brocade# show sysmon counter pp error 0
Sysmon error detected on: SLOT 1, PP 0(number of times)
****PUMA Device 0 Buffer SRAM error detect
Ingress buffer error detect = 0
Egress buffer error detect = 1
****PUMA Device 0 Control SRAM error detect
CSU : Parity error detect = 0, ECC error detect = 0
LPM0: Parity error detect = 0, ECC error detect = 0
LPM1: Parity error detect = 0, ECC error detect = 0
LPM2: Parity error detect = 0, ECC error detect = 0
LPM3: Parity error detect = 0, ECC error detect = 0
System Monitoring
280
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...