Field definitions for the show inline power detail command (Continued)
TABLE 45
Column
Definition
Cumulative port state data
NOTE
When you enable a port using the CLI, it may take 12 or more seconds before the operational state of that port is
displayed correctly in the
show inline power
output.
Slot
The Interface device/slot/port number.
#Ports Admin-On
The number of ports on the Interface module on which the
inline power
command
was issued.
#Ports Admin-Off
The number of ports on the Interface module on which the
inline power
command
was not issued.
#Ports Oper-On
The number of ports on the Interface module that are receiving inline power from
the PoE power supply.
#Ports Oper-Off
The number of ports on the Interface module that are not receiving inline power
from the PoE power supply.
#Ports Off-Denied
The number of ports on the Interface module that were denied power because of
insufficient power.
#Ports Off-No-PD
The number of ports on the Interface module to which no PDs are connected.
#Ports Off-Fault
The number of ports on the Interface module that are not receiving power because
of a subscription overload.
Total
The totals for all of the fields in the
Cumulative Port State Data
report.
Cumulative port power data
Slot
The device/slot/port number.
#Ports Pri: 1
The number of PoE ports on the Interface module that have a PoE port priority of 1.
#Ports Pri: 2
The number of PoE ports on the Interface module that have a PoE port priority of 2.
#Ports Pri: 3
The number of PoE ports on the Interface module that have a PoE port priority of 3.
Power Consumption
The total number of watts consumed by PoE power consuming devices, plus any
cable loss.
Power Allocation
The number of watts allocated to the Interface module PoE ports. This value is the
sum of the ports’ default or configured maximum power levels, or power classes
automatically detected by the FastIron PoE device.
Power over Ethernet
370
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...