PoE Capacity: 2260 Watts
Consumption: 2095 Watts
General PoE Data:
+++++++++++++++++
Slot Firmware
Version
--------------
3 Device 1: 02.1.0 Device 2: 02.1.0
4 Device 1: 02.1.0 Device 2: 02.1.0
6 02.1.0
7 Device 1: 02.1.0 Device 2: 02.1.0
8 02.1.0
Cumulative Port State Data:
+++++++++++++++++++++++++++
Slot #Ports #Ports #Ports #Ports #Ports #Ports #Ports
Admin-On Admin-Off Oper-On Oper-Off Off-Denied Off-No-PD Off-Fault
-------------------------------------------------------------------------------
3 48 0 48 0 0 0 0
4 48 0 48 0 0 0 0
6 24 0 0 24 0 24 0
7 48 0 4 44 44 0 0
8 24 0 0 24 0 24 0
-------------------------------------------------------------------------------
Total:192 0 100 92 44 48 0
... continued on next page...
... continued from previous page...
Cumulative Port Power Data:
+++++++++++++++++++++++++++
Slot #Ports #Ports #Ports Power Power Power
Pri: 1 Pri: 2 Pri: 3 Consumption Allocation Budget
------------------------------------------------------------------
3 0 0 48 513.90 W 739.200 W 65535.0 W
4 0 0 48 1346.497 W 1440.0 W 65535.0 W
6 0 0 24 0.0 W 0.0 W 65535.0 W
7 0 0 48 43.72 W 61.600 W 65535.0 W
8 0 0 24 0.0 W 0.0 W 65535.0 W
------------------------------------------------------------------
Total:0 0 192 1902.659 W 2240.800 W 327675.0 W
The following is an example of
show inline power detail
command output for an ICX 7250 stack.
ICX7250-48p-3J32-u10#show inline power detail
Power Supply Data On stack 1:
++++++++++++++++++
Power Supply Data:
++++++++++++++++++
Power Supply #1:
Max Curr: 13.3 Amps
Voltage: 54.0 Volts
Capacity: 720 Watts
Power Supply #2:
Max Curr: 6.6 Amps
Voltage: 54.0 Volts
Capacity: 360 Watts
Power Supply #3:
Max Curr: 6.6 Amps
Voltage: 54.0 Volts
Capacity: 360 Watts
POE Details Info. On Stack 1 :
General PoE Data:
+++++++++++++++++
Firmware
Version
----------------
01.2.1 Build 003
Power over Ethernet
366
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...