Explanation
The operational status of a power supply of the specified unit in a stack
changed from normal to failure.
Message Level
Informational
Message
System: Stack unit unit# Power supply power-
supply# is up
Explanation
The operational status of a power supply of the specified unit in a stack
changed from failure to normal.
Message Level
Informational
Message
System: Stack unit unit# Fan fan#
( description ), ok
Explanation
The operational status of a fan in the specified unit in a stack changed from
failure to normal.
Message Level
Informational
Message
System: Stack unit unitNumbe r Temperature
actual-temp C degrees, warning level warning-temp
C degrees, shutdown level shutdown-temp C degrees
Explanation
The actual temperature reading for a unit in a stack is above the warning
temperature threshold.
Message Level
Informational
Message
vlan vlan-id Bridge is RootBridge mac-address
(MgmtPriChg)
Explanation
802.1W changed the current bridge to be the root bridge of the given
topology due to administrative change in bridge priority.
Message Level
Informational
Message
vlan vlan-id Bridge is RootBridge mac-address
(MsgAgeExpiry)
Explanation
The message age expired on the Root port so 802.1W changed the current
bridge to be the root bridge of the topology.
Message Level
Informational
Syslog messages
FastIron Ethernet Switch Administration Guide
319
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...