To install PoE firmware on an FSX platform, use the
inline power install-firmware
command as
shown in the example.
device# inline power install-firmware module 1 tftp 10.120.54.161
fsx_poe_07400.fw
Syntax:
inline power install-firmware
module
slot
tftp ip-address
filename
Stack-unit
(FCX and ICX platforms) refers to the unit-id of the switch. If the switch is not a part of
the stack, the unit number will be the default value. The default value for stack-unit is 1.
Slot
(FSX platform) refers to the slot of the PoE module.
ip-address
refers to the IP address of the TFTP server.
Filename
refers to the name of the file, including the pathname.
ip-address
refers to the IP address of the tftp server.
Filename
refers to the name of the file, including the pathname.
To install firmware on a stack, you need to install firmware on one switch at a time with the
inline
power install-firmware stack-unit
command.
deviceFamily_Stack# inline power install-firmware stack-unit 3 tftp 10.20.65.51
icx64xx_poeplus_02.1.0.b004.fw
The process of PoE installation begins. You should see output similar to the following.
Family_Stack# Flash Memory Write (8192 bytes per dot) ..............
tftp download successful stackId = 3 file name = poe-fw
Sending PoE Firmware to Stack Unit 3.
Flash Memory Write (8192 bytes per dot) ...................
PoE: Power disabled on port 3/1/1 because of power management.
PoE: Power disabled on port 3/1/2 because of power management.
PoE: Power disabled on port 3/1/3 because of power management.
PoE: Power disabled on port 3/1/4 because of power management.
PoE: Power disabled on port 3/1/5 because of power management.
PoE: Power disabled on port 3/1/6 because of power management.
PoE: Power disabled on port 3/1/7 because of power management.
PoE: Power disabled on port 3/1/8 because of power management.
PoE: Power disabled on port 3/1/9 because of power management.
PoE: Power disabled on port 3/1/10 because of power management.
PoE: Power disabled on port 3/1/11 because of power management.
PoE: Power disabled on port 3/1/12 because of power management.
PoE: Power disabled on port 3/1/13 because of power management.
PoE: Power disabled on port 3/1/14 because of power management.
PoE: Power disabled on port 3/1/15 because of power management.
PoE: Power disabled on port 3/1/16 because of power management.
PoE: Power disabled on port 3/1/17 because of power management.
PoE: Power disabled on port 3/1/18 because of power management.
PoE: Power disabled on port 3/1/19 because of power management.
PoE: Power disabled on port 3/1/20 because of power management.
PoE: Power disabled on port 3/1/21 because of power management.
PoE: Power disabled on port 3/1/22 because of power management.
PoE: Power disabled on port 3/1/23 because of power management.
PoE: Power disabled on port 3/1/24 because of power management.
U3-MSG: PoE Warning: Upgrading firmware in slot 1....DO NOT HOTSWAP OR POWER DOWN
THE MODULE.
U3-MSG: PoE Info: FW Download on slot 1...sending download command...
U3-MSG: PoE Info: FW Download on slot 1...TPE response received.
U3-MSG: PoE Info: FW Download on slot 1...sending erase command...
U3-MSG: PoE Info: FW Download on slot 1...erase command...accepted.
U3-MSG: PoE Info: FW Download on slot 1...erasing firmware memory...
U3-MSG: PoE Info: FW Download on slot 1...erasing firmware memory...completed
U3-MSG: PoE Info: FW Download on slot 1...sending program command...
U3-MSG: PoE Info: FW Download on slot 1...sending program command...accepted.
U3-MSG: PoE Info: FW Download on slot 1...programming firmware...takes around 12
minutes....
U3-MSG: PoE Info: Firmware Download on slot 1.....10 percent completed.
U3-MSG: PoE Info: Firmware Download on slot 1.....20 percent completed.
U3-MSG: PoE Info: Firmware Download on slot 1.....30 percent completed.
U3-MSG: PoE Info: Firmware Download on slot 1.....40 percent completed.
Power over Ethernet
348
FastIron Ethernet Switch Administration Guide
53-1003625-01
Содержание FastIron
Страница 28: ...Displaying management VRF information 28 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 146: ...Displaying interface level IPv6 settings 146 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 162: ...Example 2 162 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 172: ...Clearing CDP information 172 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 216: ...Clearing cached LLDP neighbor information 216 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 228: ...FastIron Fiber optic Transceivers 228 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 284: ...show sysmon system sfm 284 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 296: ...Syslog messages for hardware errors 296 FastIron Ethernet Switch Administration Guide 53 1003625 01...
Страница 384: ...Displaying information for breakout ports 384 FastIron Ethernet Switch Administration Guide 53 1003625 01...